Bearing load P is the working load of the bearing divided by the projected area and is measured in Mpa. Without regard to the factors including fit clearance, the projected area of the bearing can be calculated as follows: bearing bore * bearing height.
Under the condition of permanent load, the bearing has higher load capacity. The actual load capacity reduces due to fatigue damage of the bearing under the condition of dynamic load or impact load.